Nominal Battery System Voltage | 24V | 48V | 24V | 48V | 48V | 48VDC | 48VDC | 48VDC |
INVERTER OUTPUT |
---|
Rated power | 4KW | 5KW | 6KW | 8.0KW | 10.0KW | 12.0KW |
Surge rating | 12000VA | 15000VA | 18000VA | 24000VA | 30000VA | 36000VA |
Capable of starting electric motor | 2HP | 2HP | 3HP | 4HP | 5HP | 6HP |
Waveform | Pure sine wave / same as input (bypass mode) |
Nominal output voltage RMS | 220V / 230V / 240VAC (±10%RMS) |
Output frequency | 50Hz / 60Hz ± 0.3Hz |
Inverter effciency(peak) | >85% | >88% |
Line mode efficiency | >95% |
Power factor | 1.0 |
Typical transfer time | 20ms(max) |
AC INPUT |
---|
Voltage | 230VAC |
Selectable voltage range | 90-280 VAC (APL) |
Frequency range | 50Hz / 60Hz |
BATTERY |
---|
Low battery voltage cutoff | 20-24VDC for 24VDC mode (40-48VDC for 48VDC mode) |
Low battery voltage recover | 21-25VDC for 24VDC mode (42-50VDC for 48VDC mode) |
High battery voltage cutoff | 30VDC for 24VDC mode (60VDC for 48VDC mode) |
High battery voltage recover | 28.5VDC for 24VDC mode (57VDC for 48VDC mode) |
Idle consumption-search mode | <30W when power saver on | <80W when power saver on |
AC CHARGER |
---|
Output voltage | Depends on battery type |
Charger AC input breaker rating | 40A | 40A | 50A | 80A | 80A | 80A |
Overcharge protection S.D. | 31.4VDC for 24VDC mode (62.8VDC for 48VDC mode ) |
Maximum charge current | 80A | 60A | 100A | 70A | 80A | 100A | 120A | 140A |
BTS |
---|
Continuous output power | Yes Variances in charging voltage & S.D. voltage base on the battery temperature |
BYPASS & PROTECTION |
Input voltage waveform | Sine wave (grid or generator) |
Nominal input frequency | 50Hz or 60Hz |
Overload protection (SMPS Load) | Circuit breaker |
Output short circuit protection | Circuit breaker |
Bypass breaker rating | 40A | 63A | 63A | 63A |
Max bypass current | 40Amp | 80Amp |
SOLAR CHARGER |
---|
Maximum PV charge current | 80A | 100A(200A optional) |
DC voltage | 24V / 48V Auto work | 48V |
Maximim PV array power | 2000W | 4000W | 2000W | 4000W | 4000W | 5000W(10000W for 200A optional) |
MPPT range @ operating voltage(VDC) | 32-145VDC for 24V mode,64-145V for 48V mode | 64~145VDC |
Maximum PV array open circuit voltage | 145VDC |
Maximum effciency | >98% |
Standby power consumption | <2W |
MECHANICAL SPECIFICATIONS |
---|
Mounting | Wall mount |
Dimensions (W*H*D) | 620*385*215mm | 670*410*215mm |
Net weight (solar CHG) (kg) | 36 | 41 | 41 | 69+2.5 | 75.75+2.5 | 75.75+2.5 |
Shipping dimensions (W*H*D) | 755*515*455mm | 884*618*443mm |
Shipping weight (Solar CHG) (kg) | 56 | 61 | 64 | 82.5+2.5 | 89+2.5 | 92+2.5 |
OTHER |
---|
Operation temperature range | 0°C to 40°C |
Storage temperature | -15°C to 60°C |
Audible noise | 60dB MAX |
Display | LED+LCD |
Loading (20GP/40GP/40HQ) | 140pcs / 280pcs / 320pcs |