Lithium Iron Phosphate Battery

LP15-24100 LiFePO4 Batteries (25.6V/100Ah)

MUSTENERGY

LiFePO4 batteries are an ideal replacement for a traditional lead acid battery, offering a drop-in solution for lead acid battery replacement. MUST’s batteries can be used individually or connected in series or parallel to create a larger system.

Key Benefits

MUSTENERGY
  • Nominal Voltage Nominal Voltage:25.6 V
  • Rated Capacity Nominal Capacity:100 Ah
  • Energy:2560 Wh
  • Charge Current Recommended Charge Current:20A
  • Charge Voltage Recommended Charge Voltage:29.2V
  • BMS Discharge Cut-Off Current BMS Discharge Cut-Off Current:300 A ±10 A (31ms)
  • BMS Discharge Cut-Off Voltage BMS Discharge Cut-Off Voltage:>16.0 V (2s) (2.0V/Cell)
  • Recommended Low Voltage Disconnect Recommended Low Voltage Disconnect:22 V (2.75V/Cell)
  • Maximum Batteries in Series Maximum Batteries in Series:8 (*Consult MUST)
  • Short Circuit Protection Short Circuit Protection:250 ~ 500 μs

Overview

MUSTENERGY

APPLICATIONS

Lithium-Iron Phosphate, or LiFePO4 Deep-Cycle batteries, are another alternative to Lead-Acid or AGM Deep-Cycle batteries. Lithium Iron Phosphate(LiFePO4 Battery) can be used in most applications that use Lead Acid, GEL or AGM type batteries.

Suitable applications include:

•Caravan
•Marine
•Golf Car
•Buggies
•Solar Storage
•Remote Monitoring
•Switching applications and more

FEATURES & BENEFITS

High cycle life

4000 cycles @80% DoD for effectively lower total of ownership cost

Longer service life

Low maintenance batteries with stable chemistry.

Built in circuit protection

Battery Management System (BMS) is incorporated against abuse.

Better storage

up to 6 months thanks to its extremely low self discharge (LSD) rate and no risk of sulphation.

Quickly recharge

Save time and increase productivity with less down time thanks to superior charge/discharge efficiency.

Extreme heat tolerance

Suitable for use in a wider range of applications where ambient temperature is unusually high: up to +60°C.

Lightweight

Lithium batteries provide more Wh/Kg while also being up to 1/3 the weight of its SLA equivalent.

CAUTIONS

•Do NOT short circuit, reverse polarity, crush or disassemble.
•Do NOT heat or incinerate.
•Do NOT immerse in any liquid.
•Store at 30~50% SOC. Recharging every 3 months is recommended. The storage area should be clean, cool, dry and ventilated.

↓↓↓Installation Portfolio------------

MUSTENERGY
MODELLP15-24100
Nominal voltage25.6V
Nominal Capacity100Ah
Nominal energy2560Wh
Life Cycles4000+ (80% DoD for effectively lower total of ownership cost)
Recommended Charge Voltage29.2V
Recommended Charge Current20.0A
End of discharge voltage20.0V
Standard methodCharge20.0A
Discharge50.0A
Maximum continuous currentCharge100.0A
Discharge100.0A
BMS Cut-Off VoltageCharge<31.2 V (3.9V/Cell)
Discharge>16.0 V (2s) (2.0V/Cell)
TemperatureCharge-4 ~ 113 ℉ (0 ~ 45℃ )
Discharge-4 ~ 131 ℉ (-20 ~ 55 ℃ )
Storage Temperature23~95 ℉ (-5~35℃ )
Shipment voltage≥25.6V
Case MaterialABS+PC
Dimension (L x W x H)483 x 170 x 240 mm
19.0 x 6.7 x 9.4”
Approx. Weight49.6 lbs (22.5 kg)
Charge retention and capacity recovery capabilityStandard charge the battery, and then put aside at room temperature for 28d or 55 ℃ for 7d, Charge retention rate≥90%, Recovery rate of charge≥90