Inverter |
Rated power | 1000W | 2000W | 3000W |
Output voltage waveform | Pure sine wave |
Output voltage regulation | 230Vac±5% |
Output frequency | 50Hz or 60Hz (±0.2Hz) |
Peak efficiency | 93% |
Nominal DC input voltage | 12Vdc | 24Vdc | 24Vdc |
Standby Consumption | <25W |
PV Input |
Max solar power input | 625W | 1500W | 2000W |
PV max charging current | 60A | 80A |
Combined charging current | 70A | 80A |
Max efficiency | 98.0% max |
PV array open circuit voltage | 75Vdc | 145Vdc | 450Vdc |
PV Array MPPT Voltage Range | 15~75Vdc | 30~120Vdc | 150~430Vdc |
AC Input |
AC input voltage | 230Vac ±5% |
Acceptable input voltage range | 170-280VAC |
Nominal input frequency | 50Hz / 60Hz (Auto detection) |
Transfer time | 10ms typical (UPS, VDE); 20ms typical (APL) |
AC Charge |
Charging current @ Nominal input voltage | 10A-20A | 20A-30A | 1-60A |
Output |
AC output | 230Vac (Socket *4pcs) |
USB (5V 2.4A) | DC output*2pcs |
USB (12V 1A) | DC output*1pcs |
VRLA Battery |
Nominal voltage | 12V | 24V |
Battery capacity | 100Ah | 100Ah | 150Ah |
Maximum continuous charging & discharge current | 100A | 100A | 150A |
Operation ambient temperature |
Charge | -20~50℃ |
Discharge | -20~50℃ |
Storage | -20~50℃ |